Latest News Thu, Nov 9, 2023 6:58 AM
Following an extensive research project involving insurers, the University of Central Lancashire, and external consultants, the FPA has developed RISC 501: Fire Test and Assessment Method for External Cladding Systems through RISCAuthority, an annually funded research scheme which conducts research on behalf of the insurance sector.
The occurrence of large cladding system fires has been increasing since 1990, which is of particular concern as a building’s cladding system has the potential to spread fire around a building, bypassing the internal fire compartments.
Combustible cladding systems are approved on high-rise buildings in the UK by the performance-based route to compliance, using the BS 8414 test method and BR 135 assessment criteria.
However, several limitations have been identified with this route in relation to the appropriateness of the fuel source, test construction, construction detailing, assessment criteria, and availability of test results.
RISC 501 has been developed to address these limitations and evaluates the fire safety performance of non-loadbearing external cladding systems, going beyond the basic life safety standards with the aim of ensuring resilient systems that can effectively prevent vertical spread.
This new test method is intended to be conducted either alongside BS 8414 so that the results can confer compliance with BR 135 and RISC 501, or as a standalone assessment. The key differences to the BS 8414 test are:
The FPA’s Technical Director, George Edwardes has been at the forefront of the research: “There have been concerns around large scale cladding testing ever since its inception in the UK. Conducting a thorough research project from an insurer’s perspective identified the areas that need improving and resulted in the development of a robust test method that reflects the built environment; a method that is appropriate for not just the minimum life safety requirement, but also for property protection. I look forward to working with industry to conduct RISC 501 testing, which will help ensure people have homes to return to after the unfortunate event of a fire. The FPA is continuously seeking ways to improve building resilience and we actively welcome collaboration for future research.”
Assessing a system against RISC 501 produces vital evidence of its robustness, providing a classification that protects both occupants and property to demonstrate systems on buildings replicate those tested, thereby reducing the insurance risk. The FPA and RISCAuthority recommend that systems are assessed against RISC 501 in addition to BS 8414 to wholly demonstrate their ability to prevent fire spread to multiple floors. RISC 501 testing is now available at the FPA’s laboratory.
Chris Miles, Commercial Director at the FPA commented: “RISC 501 offers significant improvements when compared with the current performance-based route to compliance. It also enables a route for stronger third party product and system certification, for which there is great need in the UK at present. We are pleased to now have test methodology available to support industry in evidencing robustness for the fire safety of cladding systems which is now more important than ever.”
Featured News
The British Property Federation (BPF) has called for the emerging modern industrial...
Galliford Try’s Building North East and Yorkshire business has handed over the...
BUILDING PRODUCT DIRECTORY - LATEST PRODUCTS
Straightcurve® – headquartered in Australia, is renowned for high-end innovative garden edging,...
The Kingspan RLG600 raised access floor panel is intended for light office use and is capable of...
Kingspan RHG600 Simploc is the heavy grade floor system, capable of handling up to a 12kN/m2...
CONSTRUCTION VIDEOS - LATEST VIDEOS
“Building with stone wool insulated sandwich panels” written by Professor Imperadori, is now...
Portakabin | Installation at the iconic Admiralty Arch, London