A ‘belt and braces’ approach to new fire regulations for multi-level buildings

Latest News Thu, Oct 8, 2020 10:12 AM

The value of illbruck ME010 Façade UV & Fire Membrane in delivering complete assurance

Changes to the Building Regulations and guidance in Approved Document B (ADB) have resulted in some difficulty and ambiguity in interpreting which materials are suitable for relevant buildings over 18 metres in height.

Here, Steve Wild, Technical Consultant at Construction Products Group (CPG) – which includes the illbruck brand of sealing and bonding products for windows, façades, interiors and exteriors – explores the main issues and explains the key factors to achieve a safe, robust specification process.

Under the new Building Regulations Approved Document B, membranes used as part of the external wall construction above ground level should now achieve a minimum of Class B-s3, d0 to EN13501-1 ‘Fire classification of construction products and building elements. Classification using test data from reaction to fire tests.’

The European Reaction to Fire classification (Euroclass) system is the common EU standard for assessing the qualities of building materials when subject to fire.

The system determines a product’s fire performance by measuring a comprehensive set of characteristics, including ignitability, flame spread, heat release, smoke production and tendency for producing flaming droplets/particles.

According to the European standard EN 13501-1, products will be classified in one of the seven primary classes from A1 to F according to their level of combustibility, as well as possibly belonging to additional classes according to the amount of smoke developed (s1,s2 or s3) or the amount of burning droplets or particles (d0,d1 or d2).

In order to assess the appropriate classification, a product must be tested in accordance with EN 13823 (known as a ‘single burning item’ test).

‘Reaction to fire’ evaluates specific materials’ behaviour and contribution to fire, whereas ‘resistance to fire’ assesses a product or system’s ability to resist the penetration through the product or system and prevent a temperature rise between the exposed and unexposed sides in a fully developed fire situation.

This is more commonly declared as a fire rating. The two approaches should not be confused.

Best practice in the use of membranes

Although membranes are exempt from being non-combustible (Class A1/A2-s1,d0) via Requirement B4, Regulation 7(3), they do have to be a minimum of Class B-s3, d0 when used in ‘relevant’ buildings over 18m in height.

A current Government consultation document indicates that this will reduce to 11m (in line with Scottish regulations).

illbruck have launched a fully independent accredited membrane system which achieves Class B-s1, d0 to EN 13501-1.

The illbruck system comprises ME010 Façade UV & Fire Membrane and SP025 Fire Membrane Adhesive, used to bond the membrane.

The system offers an assured, robust solution, which has been tested by MPA Hannover, a renowned, independent materials testing institute, globally recognised for testing fire behaviour of building materials.

It’s of note that any classification should include the method of fixing, which is clearly the case with ME010. A membrane which is classified in isolation as B-s3, d0 may have a lower classification when tested with the required adhesive.

In addition, it is essential that the membrane is installed in compliance with the manner in which it was tested and classified.

There is an obvious benefit and comfort for clients, specifiers and installers in knowing that there are no uncertainties associated with the specification of ME010.

Furthermore, our comprehensive training programme is available to specifiers and contractors alike, to ensure the right products are selected and installed for specific environments.

Additional benefits

As well as meeting the reaction to fire classification, ME010 fulfils other criteria of significance to specification professionals, particularly with regard to performance capabilities.

It is primarily a breather membrane – used either as a full façade application or in narrower widths as a window perimeter interface seal.

The weather performance is W1 to EN1928 (before and after ageing), whilst it is also airtight and permanently UV stable – all independently assessed. ME010 and SP025 are currently under assessment by BBA in order to further prove their performance.

This is an important attribute when considering durability.

Measuring up

Questions of compatibility should also be asked as part of the specification process.

One area of note is that, whilst EPDM membranes have been widely favoured for many years for air and weathertight applications, in the context of fire, they are non- compliant with ADB, being Class E to EN13501-1. They are also not vapour permeable, so not suitable for a breather membrane application.

Questions should also be raised as to whether a breather membrane, which meets the Class B requirement, has also achieved the W1 water tightness level to EN1928 and the appropriate vapour resistance which should be < 0.6MNs/g.

To conclude, where safety counts and system performance matters, specifiers can be assured that the selection of ME010 provides a fully compliant breather membrane solution meeting EN13501-1 Class B-s3, d0 when tested as a system with proprietary adhesive - and also meets W1 water resistance, permanent UV stability and the correct vapour permeability criteria.

More details at https://www.illbruck.com/

or contact hello@cpg-europe.com

In association with Construction Products Group


Quick Links


Company Details

United Kingdom
View Website

Featured News

Specification news
illbruck- the sustainable solution for a ‘fabric...

illbruck is signposting specifiers to the value of using its sustainable solutions...

Read More >>

Specification news
Nullifire puts Innovation, Expertise, Protection and...

Nullifire, the leader in smart passive fire protection, has launched a new campaign,...

Read More >>