Bauder unveils Blue Roof system at ecobuild 2018

Sustainability Wed, Mar 7, 2018 7:34 AM

The BauderBLUE Roof System is a sustainable drainage method designed to attenuate and manage stormwater on a flat roof over a 24-hour period via a restrictive flow outlet.

A BauderBLUE roof is designed specifically for each individual project. It is a solution for urban areas where options for ground-based attenuation systems are limited, and in particular, where construction is being carried out within flood sensitive areas.

The BauderBLUE roof system has no moving parts, is simple to install and easy to maintain. It is designed to slow the release of rainwater into the drainage system and to discharge the water completely over a 24-hour period.

Development and expansion of towns and cities has seen exponential use of impervious surfaces causing artificially high rates of rainwater runoff. In measures to prevent flooding, planners are restricting the amount of rainwater leaving a site via the drainage system which can be limited to 5-10 litres per second per hectare, the same flow rates for regional greenfield sites.

This rooftop sustainable urban drainage system (SuDS) has weight load implications and the project’s structural engineer will need to be engaged with the design process from an early stage.

The specifically engineered outlet restricts the discharge of stormwater to a calculated and predesigned flow rate to significantly slow down the volume of water leaving the site. As the storm passes, water continues to discharge from the roof at a controlled rate which helps to avoid downstream or localised flooding.

The BauderBLUE Roof system can be constructed at either rooftop or podium level. The designed void space between the flat roof waterproofing membrane and hard or soft landscaping finish allows the stormwater to attenuate.

Fundamentally, a blue roof is designed to attenuate water and should not be considered as a water storage solution.

The Bauder Blue Roof is designed for use with either the Bauder Total Green Roof System as a warm roof construction or the Bauder Hot Melt cold roof construction. The design of the blue roof requires:

  • Specific flow restrictor outlets to meet the requirements of planning for total allowable water discharge.
  • Emergency overflows included in the design, unconnected to the blue roof outlets, to discharge the rainwater should the maximum height of rainwater attenuated be reached.
  • Free-flowing multi-directional water movement within the void space to the specifically engineered outlets.
  • Minimal or elimination of penetrations in the area where water is to be attenuated, other than the rainwater outlets or emergency overflows that are required for drainage functionality. In some instances, it may be possible to individually isolate the roof penetration from the blue roof SuDS to prevent any possible water ingress from contaminating the insulation.
  • Roof design must adhere to the British Standards and Systems Codes of Practice for waterproofing and roof detailing.

The baseplate of the blue roof system sits within a standard Bauder outlet and slows water from leaving the roof via a calculated number of restrictive flow holes. The number of flow holes, up to a maximum of 12, is calculated to reflect the SuDS calculation for permitted discharge rate for the site.

If, in the event of a storm of greater magnitude than 1 in 100 years plus 40% for climate change, then water will evacuate the roof through the central overflow.

The design of every Bauder blue roof is individual to the project and geographical location. We use details of the roof area and the drainage requirements for the site to produce a roof specific discharge report to show the following:

  • Storm profile for the roof during a 1 in 100-year storm event + 40% for climate change.
  • Maximum attenuation volume on the roof.
  • Number of outlets required, complete with an assigned number of control holes, restricting the flow of water in line with the discharge rate for site.
  • The depth of void required on the roof on to which any landscaping finish can be installed.

The report and series of calculations allows us to produce the most effective scheme for your project.

The Bauder blue roof outlet overflow is inserted into the baseplate and measured, marked and cut to the specified Hmax for the roof. The entire blue roof outlet is protected with the Bauder ALU250 Inspection Chamber which allows for ease of access during regular maintenance.

Blue roofs require regular maintenance and inspection of the outlets to ensure the drainage holes are free of debris or blockages. Inspections should take place following any significant storm event, any notable traffic or remedial works that take place on or around the roof, and following leaf fall during the autumn months to ensure leaf litter is not causing obstruction.

In association with Bauder Limited


Quick Links


Company Details

70 Landseer Road
Ipswich
IP3 0DH
United Kingdom
T: 01473 257671
View Website
  • Twitter
  • Youtube
  • Linkedin

Featured News

Specification news
Utilising roof space to achieve Biodiversity Net-Gain

In 2024 the UK government introduced Biodiversity Net Gain (BNG) legislation to...

Read More >>

Specification news
Bauder waterproofing systems are now CCPI verified

As a market leader in bringing high-quality products and systems to the roofing and...

Read More >>