Recladding work must meet building regulations advises expert panel

Latest News Fri, Jul 14, 2017 3:49 PM

The Department for Communities and Local Government has written to all building control bodies in England highlighting key Building Regulations requirements when cladding work on high rise buildings over 18 metres tall is undertaken.

This followed advice from the Independent Expert Advisory Panel whose members were particularly concerned that further risks are not created in any new works undertaken by building owners.

At their third meeting the Independent Expert Advisory Panel recommended that it would be wise to draw attention to the need to ensure that any recladding work complies with all relevant Building Regulations’ requirements. In particular requirements on structural safety, resistance to moisture penetration and build up, and energy efficiency need to be considered – as well as ensuring that the fire safety requirements are met.

Building control bodies are responsible for checking that work complies with Building Regulations’ requirements. It is the responsibility of those carrying out the work to ensure that the provisions of the regulations are fully met.

The advice from the Department has been sent to all building control bodies in England including local authorities building control departments and private sector Approved Inspectors. It sets out the Department’s view that if building owners consider that they need to re-clad their building, for example following the results of recent screening for identification of the type of ACM cladding in use, this should be considered as building work and therefore subject to Building Regulations’ requirements.

The letter particularly draws the attention of building control bodies to the following:

  • Approaches to demonstrating compliance with fire safety requirements, for example ensuring that cladding and insulation used are of limited combustibility or that a whole wall cladding system BS 8414 test is undertaken. The British Standard 8414 requires that a wall with a complete cladding system – including panels and insulation – fixed to it, is then subject it to a fire that replicates a severe fire in a flat breaking out of a window and whether it then spread up the outside wall.
  • Where panels are removed for inspection or testing purposes, the integrity of the whole cladding system needs to be maintained.
  • The structural design of any replacement cladding needs to be checked – it should not be assumed that existing fixings and systems are suitable for replacement systems.
  • The need to ensure that replacement cladding systems or components protect the building adequately from rain and condensation.
    Guidance on how to meet energy efficiency requirements when recladding.

Featured News

Specification news
NAO identifies need for improvements to developer...

Weaknesses in the Ministry of Housing, Communities & Local Government’s (MHCLG)...

Read More >>

Specification news
IStructE’s Structural Safety and Risk conference...

The Institution of Structural Engineers’ (IStructE) Structural Safety and Risk...

Read More >>

BUILDING PRODUCT LIBRARY - LATEST BROCHURES

Proctors Spacetherm Building & Construction Brochure

Proctors Spacetherm...
By A Proctor Group Ltd.

Download Now >>

Proctors Proctor Passive Brochure

Proctors Proctor Pas...
By A Proctor Group Ltd.

Download Now >>

Proctors Air Brochure Brochure

Proctors Air Brochur...
By A Proctor Group Ltd.

Download Now >>

Proctors Modular & Offsite Solutions Brochure

Proctors Modular & O...
By A Proctor Group Ltd.

Download Now >>

Proctors Hamm Principles Brochure

Proctors Hamm Princi...
By A Proctor Group Ltd.

Download Now >>

BUILDING PRODUCT DIRECTORY - LATEST PRODUCTS

SOPRALENE FLAM 180 AF
SOPRALENE FLAM 180 AF

Membrane composed of elastomer modified bitumen and a non woven polyester reinforcement.The upper...

Read More >>

FLAGON SR DE PVC
FLAGON SR DE PVC

Membrane composed of flexible PVC and a polyester reinforcement. Available in different RAL...

Read More >>

FLAGON S PVC
FLAGON S PVC

Membrane composed of flexible PVC. Available in different RAL Colours.Used for detailing work. The...

Read More >>

CONSTRUCTION VIDEOS - LATEST VIDEOS

Why our Canopies Last Longer
Why our Canopies Last Longer

https://www.aandslandscape.co.uk/ Find out why A&S Landscape Canopies last longer than alternatives....

Watch Now >>

Enclosed Dining Canopy - Hampton Gardens School
Enclosed Dining Canopy - Hampton Gardens School

A&S Landscape designed and installed a large enclosed, curved roof canopy for Hampton Gardens School...

Watch Now >>

Dining Area Canopy at John Spendluffe Technology College
Dining Area Canopy at John Spendluffe Technology College

We designed and installed a new dining area canopy for John Spendluffe Technology College. This has...

Watch Now >>