SE Controls provides comfort and safety at new hospital

Latest News Tue, Mar 22, 2016 4:59 PM

SE Controls provides comfort and safety at new hospital

A combined smoke and natural ventilation solution from SE Controls is helping create a comfortable and safe environment for patients, visitors and staff at Salford Royal Hospital’s new £90 million Hope Building. Designed by architects HKS and constructed by Balfour Beatty, as part of the Salford Royal NHS Foundation Trust’s £200 million redevelopment programme, the five storey Hope Building houses a new A&E department as well as providing 242 beds, an emergency assessment unit and critical care facilities. SE Controls developed the fire engineered smoke and natural ventilation solution around the original fire specification and worked closely with the consultants to create an effective and reliable system that maximises comfort, safety and energy efficiency by linking in to both the building management system (BMS) and the separate fire alarm system. Within the hospital, the smoke and natural ventilation system is split into two zones to allow maximum control over the temperatures and ventilation needs in both the main concourse and the atrium areas of the building, by using a series of louvres, roof vents and atrium vents controlled by the BMS. In normal operation, localised sensors throughout the building monitor the temperatures and their patterns of change, feeding constant information to the BMS, which manages the proportional opening and closing of the vents and louvres. This not only ensures that temperatures remain within specified limits but also that the building has a constant flow of fresh air. SE Controls’ solution also takes account of adverse weather conditions, such as excessively high winds or rain, to ensure that vents are automatically closed to stop the ingress of water and limit any possible damage. In the event of fire, the alarm system over-rides the BMS, which instantly opens the smoke vents and louvres fully to create a smoke free escape route and access for fire services. The potential for false alarms and accidental triggering is also addressed by the SE Controls system, as any manual activation by a Manual Control Point (MCP) or individual smoke detector requires a secondary confirmation signal from the aspirator monitoring system. However, if the aspiration system detects a fault, then it switches to ‘fault mode’ where no confirmation signal is required to activate the smoke ventilation if triggered manually or by a smoke detector. Further fail-safe back up is provided by a separate fully monitored battery back up system in compliance with the requirements of EN12101 standard, as well as a further supply taken from the hospital’s own secondary power system, which effectively provides the entire system with two independent back up supplies. Mark Hargreaves, SE Controls’ Commercial Manager, explained: “Fire safety is a critical aspect of any building design and in hospitals where there are a large number of people with limited mobility, it is vital that escape routes are kept clear for extended periods to enable them to escape. By combining fire engineered smoke ventilation with highly effective natural ventilation as an integrated solution, the system not only provides failsafe protection, but also provides a comfortable environment for the building’s occupants.” SE Controls specialises in the design, project management and installation of advanced smoke ventilation and natural ventilation solutions to meet the needs of architects, contractors, building services engineers and facilities managers worldwide. Further information on SE Controls’ products, solutions and projects can be obtained by visiting www.secontrols.com or calling +44 (0) 1543 443060.

In association with SE Controls


Quick Links


Company Details

Lancaster House
Wellington Crescent
Lichfield
Staffordshire
WS13 8RZ
United Kingdom
T: 01543 443060
View Website
  • Facebook
  • Twitter
  • Linkedin

Featured News

Specification news
Nakheel Mall

Nakheel Mall, Dubai’s 435,000 sq.metre retail and lifestyle centre located in the...

Read More >>

Specification news
SE Controls feels the power with Bristol’s...

Electricity House, Crest Nicholson Homes’ stylish city centre apartment development...

Read More >>

BUILDING PRODUCT LIBRARY - LATEST BROCHURES

Maintenance Solutions  Brochure

Maintenance Solution...
By SE Controls

Download Now >>

SE Cloudlink Brochure

SE Cloudlink
By SE Controls

Download Now >>

Product Specification Guide Brochure

Product Specificatio...
By SE Controls

Download Now >>

Corporate Overview Brochure

Corporate Overview
By SE Controls

Download Now >>

Understanding Smoke Ventilation Compliance Brochure

Understanding Smoke...
By SE Controls

Download Now >>

BUILDING PRODUCT DIRECTORY - LATEST PRODUCTS

Smoke Ventilation - End of wall corridor AOV
Smoke Ventilation - End of wall corridor AOV

If the corridor extends to the external wall an AOV can be installed to remove smoke from the common...

Read More >>

Smoke Ventilation- Escape Stair / Fire Fighting Stair
Smoke Ventilation- Escape Stair / Fire Fighting Stair

The prime objective of a smoke control strategy is to keep the escape stair free from smoke, by...

Read More >>

Smoke Ventilation- Mechanical Smoke Shaft
Smoke Ventilation- Mechanical Smoke Shaft

If a prescribed and certified solution is not a viable option for the building design a fire...

Read More >>

CONSTRUCTION VIDEOS - LATEST VIDEOS

SE Controls Overview
SE Controls Overview

This video is an overview of the comprehensive range of solutions provided by SE Controls for...

Watch Now >>